Addressable 1~2 loops (324~510 points) Control Panel SEC3002 Addressable 1~2 loops (324~510 points) Control Panel SEC3002

SEC3002 system represents the latest generation of addressable fire alarm control panel designed to comply with the latest versions of EN standard with qualities of simple installation, operation and easy maintenance. The wide range of SEC3002 configurations include standalone operation and networking with up to twenty panels for small to large sized applications.

Quantity:
Share this:

Product Description

SEC3002 represents FIRETECH latest generation of addressable fire alarm control panel designed to comply with the latest versions of EN 54 parts 2&4 with qualities of simple installation, operation and easy maintenance. The wide range of SEC3002 configurations include standalone operation and networking with up to twenty panels for small to large sized applications.


ModelDT106
Device Loops1 to 4 loops, Class A or B, each loop supporting up to 252 device addresses
Max. Current8.0 A DC total, 2.0 A DC each max. per circuit
Primary Power110-120 VAC, 60Hz, 3.86A max. 220-240 VAC, 50Hz, 1.96A max.
Base Panel Current Standby333 mA
Base Panel Current Alarm354 mA
Input Zones64 max.
Remote AnnunciatorMax. 84, RS-485 Class B, Data line length: 15,443 ft. (4,708 m) when using 12 AWG wiring
Operating Voltage24 VDC
Auxiliary Power Output CircuitAux power: 24VDC nominal at 500mA (standby), 1.2A (alarm)
Loop Circuit-
Loop Circuit Maximum loop resistance-
Loop circuit Maximum loop capacitanceOne programmable relay,4 non-programmable status relays Status: Alarm/Supervisory/Trouble/Monitor
Loop circuit SLC output rangeTotal of 4 circuits supported, total power available 8A, 2 Class A or 2 Class B circuits on each NOU
Loop circuit Operating current0 to 6.6 kΩ
Max. resistance between isolatorsForm C 30VDC at 2A (pf=0.35)
BatteriesForm C 30VDC at 2A (pf=0.35)
Batteries typeForm C 30VDC at 2A (pf=0.35)
Relays OutputTemperature: 0 to 49˚C (32 to 120˚F) Relative humidity: 0 to 93% non-condensing
Relays OutputAll terminals rated for 12 to 18AWG (0.75 to 2.5 mm²)
Notification Appliance Circuits20 Ω
Notification Appliance Circuits0.1 µF
Notification Appliance Circuits20.4 to 26.4Vdc. (24 V nominal)
Notification Appliance CircuitsStand by: 100 mA; Alarm: 220 mA (fully loaded loop)
Ground Fault ImpedanceLimited only by overall wire run lengths, Max. 20 Isolators per loop
Alarm Contact-
Trouble ContactForm C Contact, Contact Rating: 2A 30VDC, Power Factor Ration:0.35
Supervisory ContactMaximum Current: 2A per NAC circuit, Alarm Voltage: 24V nominal
EnvironmentalSupports one regulated 24VDC NAC, or 4 special application 24VDC NAC
Terminal RatingBell code: Temporal 3, Max line loss: 1.8V


Features

  • LPCB and CPR approval.

  • 324 addresses for one loop or 510 addresses for two loops.

  • 4.3" color screen LCD, resolution of 480x272.

  • Zone indication and control panel for 32 zones give a quick indication of the location of an alarm.

  • Record capacity of 1000 historical events with date/time stamp.

  • Integral power supply and battery.

  • Integral printer.

  • A standalone programmable conventional sounder circuit output.

  • Flexible and intuitive cause and effect programming on front of panel.

  • Output module manual start/stop facilitates the commissioning and operating.

  • It supports the detector/module testing individually.

  • USB port makes the load and save of configuration data or historical data convenient for system commissioning -and maintenance.

  • Hierarchy management with three access levels.

  • Anti-tamper protection by a key lock.

  • Networkable: CAN bus for interconnection of up to 20 FACPs and Ethernet for up to 255 FACPs.


×